Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: In pre-operative planning for total hip arthroplasty (THA), femoral offset (FO) is frequently underestimated on AP pelvis radiographs as a result of inaccurate patient positioning, imprecise magnification, and radiographic beam divergence. The aim of the present study was to evaluate the accuracy and reliability of predicting three-dimensional (3-D) FO from standardised AP pelvis radiographs. METHODS: In a retrospective cohort study, pre-operative AP pelvis radiographs, AP hip radiographs and CT scans of a consecutive series of 345 patients (345 hips, 146 males, 199 females, mean age 60 (range: 40-79) years, mean body-mass-index 27 (range: 19-57)kg/m(2)) with primary end-stage hip OA were reviewed. Patients were positioned according to a standardised protocol and all images were calibrated. Using validated custom programmes, FO was measured on corresponding radiographs and CT scans. Measurement reliability was evaluated using intra-class-correlation-coefficients. To predict 3-D FO from AP pelvis measurements and to assess the accuracy compared to CT, the entire cohort was randomly split into subgroups A and B. Gender specific regression equations were derived from group A (245 patients) and the accuracy of prediction was evaluated in group B (100 patients) using Bland-Altman plots. RESULTS: In the entire cohort, mean FO was 39.2mm (95%CI: 38.5-40.0mm) on AP pelvis radiographs, 44.1mm (95%CI: 43.4-44.9mm) on AP hip radiographs and 44.6mm (95%CI: 44.0-45.2mm) on CT scans. In group B, we observed no significant difference between gender specific predicted FO (males: 48.0mm, 95%CI: 47.1-48.8mm; females: 42.0mm, 95%CI: 41.1-42.8mm) and FO as measured on CT (males: 47.7mm, 95%CI: 46.1-49.4mm, p=0.689; females: 41.6mm, 95%CI: 40.3-43.0mm, p=0.607). CONCLUSIONS: The present study suggests that FO can be accurately and reliably predicted from AP pelvis radiographs in patients with primary end-stage hip osteoarthritis. Our findings support the surgeon in pre-operative templating on AP-pelvis radiographs and may improve offset and limb length restoration in THA without the routine performance of additional radiographs or CT.

Original publication

DOI

10.1016/j.ejrad.2013.02.040

Type

Journal article

Journal

Eur j radiol

Publication Date

08/2013

Volume

82

Pages

1278 - 1285

Keywords

Adult, Aged, Cohort Studies, Female, Femur, Hip Joint, Humans, Imaging, Three-Dimensional, Male, Middle Aged, Osteoarthritis, Hip, Patient Positioning, Pelvis, Prevalence, Reproducibility of Results, Retrospective Studies, Sensitivity and Specificity, Tomography, X-Ray Computed, United Kingdom