{
    "items": [
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/721089\" title=\"Magnetic targeting to enhance microbubble delivery in an occluded microarterial bifurcation.\" class=\"state-synced\">Magnetic targeting to enhance microbubble delivery in an occluded microarterial bifurcation.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Ultrasound and microbubbles have been shown to accelerate the breakdown of blood clots both in vitro and in vivo. Clinical translation of this technology is still limited, however, in part by inefficient microbubble delivery to the thrombus. This study examines the obstacles to delivery posed by fluid dynamic conditions in occluded vasculature and investigates whether magnetic targeting can improve microbubble delivery. A 2D computational fluid dynamic model of a fully occluded Y-shaped microarterial bifurcation was developed to determine: (i) the fluid dynamic field in the vessel with inlet velocities from 1-100\u2009mm s-1 (corresponding to Reynolds numbers 0.25-25); (ii) the transport dynamics of fibrinolytic drugs; and (iii) the flow behavior of microbubbles with diameters in the clinically-relevant range (0.6-5 \u00b5m). In vitro experiments were carried out in a custom-built microfluidic device. The flow field was characterized using tracer particles, and fibrinolytic drug transport was assessed using fluorescence microscopy. Lipid-shelled magnetic microbubbles were fluorescently labelled to determine their spatial distribution within the microvascular model. In both the simulations and experiments, the formation of laminar vortices and an abrupt reduction of fluid velocity were observed in the occluded branch of the bifurcation, severely limiting drug transport towards the occlusion. In the absence of a magnetic field, no microbubbles reached the occlusion, remaining trapped in the first vortex, within 350 \u00b5m from the bifurcation center. The number of microbubbles trapped within the vortex decreased as the inlet velocity increased, but was independent of microbubble size. Application of a magnetic field (magnetic flux density of 76 mT, magnetic flux density gradient of 10.90 T m-1 at the centre of the bifurcation) enabled delivery of microbubbles to the occlusion and the number of microbubbles delivered increased with bubble size and with decreasing inlet velocity.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/813546\" title=\"Mechanisms of microbubble mediated drug delivery\" class=\"state-synced\">Mechanisms of microbubble mediated drug delivery</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">There is now a substantial literature demonstrating the potential of surfactant stabilised microbubbles as drug delivery agents; particularly in combination with therapeutic ultrasound. Microbubbles provide a means of encapsulating drugs to avoid interaction with healthy tissue.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/521261\" title=\"Biologically and Acoustically Compatible Chamber for Studying Ultrasound-Mediated Delivery of Therapeutic Compounds.\" class=\"state-synced\">Biologically and Acoustically Compatible Chamber for Studying Ultrasound-Mediated Delivery of Therapeutic Compounds.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Ultrasound (US), in combination with microbubbles, has been found to be a potential alternative to viral therapies for transfecting biological cells. The translation of this technique to the clinical environment, however, requires robust and systematic optimization of the acoustic parameters needed to achieve a desired therapeutic effect. Currently, a variety of different devices have been developed to transfect cells in vitro, resulting in a lack of standardized experimental conditions and difficulty in comparing results from different laboratories. To overcome this limitation, we propose an easy-to-fabricate and cost-effective device for application in US-mediated delivery of therapeutic compounds. It comprises a commercially available cell culture dish coupled with a silicon-based \"lid\" developed in-house that enables the device to be immersed in a water bath for US exposure. Described here are the design of the device, characterization of the sound field and fluid dynamics inside the chamber and an example protocol for a therapeutic delivery experiment.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/682292\" title=\"A versatile method for the preparation of particle-loaded microbubbles for multimodality imaging and targeted drug delivery.\" class=\"state-synced\">A versatile method for the preparation of particle-loaded microbubbles for multimodality imaging and targeted drug delivery.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Microbubbles are currently in clinical use as ultrasound contrast agents and under active investigation as mediators of ultrasound therapy. To improve the theranostic potential of microbubbles, nanoparticles can be attached to the bubble shell for imaging, targeting and/or enhancement of acoustic response. Existing methods for fabricating particle-loaded bubbles, however, require the use of polymers, oil layers or chemical reactions for particle incorporation; embed/attach the particles that can reduce echogenicity; impair biocompatibility; and/or involve multiple processing steps. Here, we describe a simple method to embed nanoparticles in a phospholipid-coated microbubble formulation that overcomes these limitations. Magnetic nanoparticles are used to demonstrate the method with a range of different microbubble formulations. The size distribution and yield of microbubbles are shown to be unaffected by the addition of the particles. We further show that the microbubbles can be retained against flow using a permanent magnet, can be visualised by both ultrasound and magnetic resonance imaging (MRI) and can be used to transfect SH-SY5Y cells with fluorescent small interfering RNA under the application of a magnetic field and ultrasound field.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/668980\" title=\"Ultrasound-Enhanced siRNA Delivery Using Magnetic Nanoparticle-Loaded Chitosan-Deoxycholic Acid Nanodroplets.\" class=\"state-synced\">Ultrasound-Enhanced siRNA Delivery Using Magnetic Nanoparticle-Loaded Chitosan-Deoxycholic Acid Nanodroplets.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Small interfering RNA (siRNA) has significant therapeutic potential but its clinical translation has been severely inhibited by a lack of effective delivery strategies. Previous work has demonstrated that perfluorocarbon nanodroplets loaded with magnetic nanoparticles can facilitate the intracellular delivery of a conventional chemotherapeutic drug. The aim of this study is to determine whether a similar agent can provide a means of delivering siRNA, enabling efficient transfection without degradation of the molecule. Chitosan-deoxycholic acid nanoparticles containing perfluoropentane and iron oxide (d 0 = 7.5 \u00b1 0.35 nm) with a mean hydrodynamic diameter of 257.6 \u00b1 10.9 nm are produced. siRNA (AllStars Hs cell death siRNA) is electrostatically bound to the particle surface and delivery to lung cancer cells and breast cancer cells is investigated with and without ultrasound exposure (500 kHz, 1 MPa peak-to-peak focal pressure, 40 cycles per burst, 1 kHz pulse repetition frequency, 10 s duration). The results show that siRNA functionality is not impaired by the treatment protocol and that the nanodroplets are able to successfully promote siRNA uptake, leading to significant apoptosis (52.4%) 72 h after ultrasound treatment.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/673329\" title=\"Understanding the dynamics of superparamagnetic particles under the influence of high field gradient arrays.\" class=\"state-synced\">Understanding the dynamics of superparamagnetic particles under the influence of high field gradient arrays.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">The aim of this study was to characterize the behaviour of superparamagnetic particles in magnetic drug targeting (MDT) schemes. A 3-dimensional mathematical model was developed, based on the analytical derivation of the trajectory of a magnetized particle suspended inside a fluid channel carrying laminar flow and in the vicinity of an external source of magnetic force. Semi-analytical expressions to quantify the proportion of captured particles, and their relative accumulation (concentration) as a function of distance along the wall of the channel were also derived. These were expressed in terms of a non-dimensional ratio of the relevant physical and physiological parameters corresponding to a given MDT protocol. The ability of the analytical model to assess magnetic targeting schemes was tested against numerical simulations of particle trajectories. The semi-analytical expressions were found to provide good first-order approximations for the performance of MDT systems in which the magnetic force is relatively constant over a large spatial range. The numerical model was then used to test the suitability of a range of different designs of permanent magnet assemblies for MDT. The results indicated that magnetic arrays that emit a strong magnetic force that varies rapidly over a confined spatial range are the most suitable for concentrating magnetic particles in a localized region. By comparison, commonly used magnet geometries such as button magnets and linear Halbach arrays result in distributions of accumulated particles that are less efficient for delivery. The trajectories predicted by the numerical model were verified experimentally by acoustically focusing magnetic microbeads flowing in a glass capillary channel, and optically tracking their path past a high field gradient Halbach array.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/592522\" title=\"Facile and cost-effective production of microscale PDMS architectures using a combined micromilling-replica moulding (\u03bcMi-REM) technique.\" class=\"state-synced\">Facile and cost-effective production of microscale PDMS architectures using a combined micromilling-replica moulding (\u03bcMi-REM) technique.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">We describe a cost-effective and simple method to fabricate PDMS-based microfluidic devices by combining micromilling with replica moulding technology. It relies on the following steps: (i) microchannels are milled in a block of acrylic; (ii) low-cost epoxy adhesive resin is poured over the milled acrylic block and allowed to cure; (iii) the solidified resin layer is peeled off the acrylic block and used as a mould for transferring the microchannel architecture onto a PDMS layer; finally (iv) the PDMS layer is plasma bonded to a glass surface. With this method, microscale architectures can be fabricated without the need for advanced technological equipment or laborious and time-consuming intermediate procedures. In this manuscript, we describe and validate the microfabrication procedure, and we illustrate its applicability to emulsion and microbubble production.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/659721\" title=\"Modulation of the molecular arrangement in artificial and biological membranes by phospholipid-shelled microbubbles.\" class=\"state-synced\">Modulation of the molecular arrangement in artificial and biological membranes by phospholipid-shelled microbubbles.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">The transfer of material from phospholipid-coated microbubbles to cell membranes has been hypothesized to play a role in ultrasound-mediated drug delivery. In this study, we employed quantitative fluorescence microscopy techniques to investigate this phenomenon in both artificial and biological membrane bilayers in an acoustofluidic system. The results of the present study provide strong evidence for the transfer of material from microbubble coatings into cell membranes. Our results indicate that transfer of phospholipids alters the organization of molecules in cell membranes, specifically the lipid ordering or packing, which is known to be a key determinant of membrane mechanical properties, protein dynamics, and permeability. We further show that polyethylene-glycol, used in many clinical microbubble formulations, also has a major impact on both membrane lipid ordering and the extent of lipid transfer, and that this occurs even in the absence of ultrasound exposure.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/489806\" title=\"Microfluidic system for high throughput characterisation of echogenic particles.\" class=\"state-synced\">Microfluidic system for high throughput characterisation of echogenic particles.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Echogenic particles, such as microbubbles and volatile liquid micro/nano droplets, have shown considerable potential in a variety of clinical diagnostic and therapeutic applications. The accurate prediction of their response to ultrasound excitation is however extremely challenging, and this has hindered the optimisation of techniques such as quantitative ultrasound imaging and targeted drug delivery. Existing characterisation techniques, such as ultra-high speed microscopy provide important insights, but suffer from a number of limitations; most significantly difficulty in obtaining large data sets suitable for statistical analysis and the need to physically constrain the particles, thereby altering their dynamics. Here a microfluidic system is presented that overcomes these challenges to enable the measurement of single echogenic particle response to ultrasound excitation. A co-axial flow focusing device is used to direct a continuous stream of unconstrained particles through the combined focal region of an ultrasound transducer and a laser. Both the optical and acoustic scatter from individual particles are then simultaneously recorded. Calibration of the device and example results for different types of echogenic particle are presented, demonstrating a high throughput of up to 20 particles per second and the ability to resolve changes in particle radius down to 0.1 \u03bcm with an uncertainty of less than 3%.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/810919\" title=\"Characterisation of Functionalised Microbubbles for Ultrasound Imaging and Therapy\" class=\"state-synced\">Characterisation of Functionalised Microbubbles for Ultrasound Imaging and Therapy</a>\n            </h4>\n            \n            \n            \n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/623335\" title=\"Liposome production by microfluidics: potential and limiting factors.\" class=\"state-synced\">Liposome production by microfluidics: potential and limiting factors.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">This paper provides an analysis of microfluidic techniques for the production of nanoscale lipid-based vesicular systems. In particular we focus on the key issues associated with the microfluidic production of liposomes. These include, but are not limited to, the role of lipid formulation, lipid concentration, residual amount of solvent, production method (including microchannel architecture), and drug loading in determining liposome characteristics. Furthermore, we propose microfluidic architectures for the mass production of liposomes with a view to potential industrial translation of this technology.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/684020\" title=\"Electroformation of Giant Unilamellar Vesicles on Stainless Steel Electrodes.\" class=\"state-synced\">Electroformation of Giant Unilamellar Vesicles on Stainless Steel Electrodes.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Giant unilamellar vesicles (GUVs) are well-established model systems for studying membrane structure and dynamics. Electroformation, also referred to as electroswelling, is one of the most prevalent methods for producing GUVs, as it enables modulation of the lipid hydration process to form relatively monodisperse, defect-free vesicles. Currently, however, it is expensive and time-consuming compared with other methods. In this study, we demonstrate that 1,2-dioleoyl-sn-glycero-3-phosphatidylcholine GUVs can be prepared readily at a fraction of the cost on stainless steel electrodes, such as commercially available syringe needles, without any evidence of lipid oxidation or hydrolysis.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/691222\" title=\"Spectral imaging toolbox: segmentation, hyperstack reconstruction, and batch processing of spectral images for the determination of cell and model membrane lipid order.\" class=\"state-synced\">Spectral imaging toolbox: segmentation, hyperstack reconstruction, and batch processing of spectral images for the determination of cell and model membrane lipid order.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">BACKGROUND: Spectral imaging with polarity-sensitive fluorescent probes enables the quantification of cell and model membrane physical properties, including local hydration, fluidity, and lateral lipid packing, usually characterized by the generalized polarization (GP) parameter. With the development of commercial microscopes equipped with spectral detectors, spectral imaging has become a convenient and powerful technique for measuring GP and other membrane properties. The existing tools for spectral image processing, however, are insufficient for processing the large data sets afforded by this technological advancement, and are unsuitable for processing images acquired with rapidly internalized fluorescent probes. RESULTS: Here we present a MATLAB spectral imaging toolbox with the aim of overcoming these limitations. In addition to common operations, such as the calculation of distributions of GP values, generation of pseudo-colored GP maps, and spectral analysis, a key highlight of this tool is reliable membrane segmentation for probes that are rapidly internalized. Furthermore, handling for hyperstacks, 3D reconstruction and batch processing facilitates analysis of data sets generated by time series, z-stack, and area scan microscope operations. Finally, the object size distribution is determined, which can provide insight into the mechanisms underlying changes in membrane properties and is desirable for e.g. studies involving model membranes and surfactant coated particles. Analysis is demonstrated for cell membranes, cell-derived vesicles, model membranes, and microbubbles with environmentally-sensitive probes Laurdan, carboxyl-modified Laurdan (C-Laurdan), Di-4-ANEPPDHQ, and Di-4-AN(F)EPPTEA (FE), for quantification of the local lateral density of lipids or lipid packing. CONCLUSIONS: The Spectral Imaging Toolbox is a powerful tool for the segmentation and processing of large spectral imaging datasets with a reliable method for membrane segmentation and no ability in programming required. The Spectral Imaging Toolbox can be downloaded from https://uk.mathworks.com/matlabcentral/fileexchange/62617-spectral-imaging-toolbox .</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/615264\" title=\"Optimized shapes of magnetic arrays for drug targeting applications\" class=\"state-synced\">Optimized shapes of magnetic arrays for drug targeting applications</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Arrays of permanent magnet elements have been utilized as light-weight, inexpensive sources for applying external magnetic fields in magnetic drug targeting applications, but they are extremely limited in the range of depths over which they can apply useful magnetic forces. In this paper, designs for optimized magnet arrays are presented, which were generated using an optimization routine to maximize the magnetic force available from an arbitrary arrangement of magnetized elements, depending on a set of design parameters including the depth of targeting (up to 50 mm from the magnet) and direction of force required. A method for assembling arrays in practice is considered, quantifying the difficulty of assembly and suggesting a means for easing this difficulty without a significant compromise to the applied field or force. Finite element simulations of in vitro magnetic retention experiments were run to demonstrate the capability of a subset of arrays to retain magnetic microparticles against flow. The results suggest that, depending on the choice of array, a useful proportion of particles (more than 10%) could be retained at flow velocities up to 100 mm/s or to depths as far as 50 mm from the magnet. Finally, the optimization routine was used to generate a design for a Halbach array optimized to deliver magnetic force to a depth of 50 mm inside the brain.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/570770\" title=\"Nanoparticle-Loaded Protein-Polymer Nanodroplets for Improved Stability and Conversion Efficiency in Ultrasound Imaging and Drug Delivery\" class=\"state-synced\">Nanoparticle-Loaded Protein-Polymer Nanodroplets for Improved Stability and Conversion Efficiency in Ultrasound Imaging and Drug Delivery</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">A new formulation of volatile nanodroplets stabilized by a protein and polymer coating and loaded with magnetic nanoparticles is developed. The droplets show enhanced stability and phase conversion efficiency upon ultrasound exposure compared with existing formulations. Magnetic targeting, encapsulation, and release of an anticancer drug are demonstrated in vitro with a 40% improvement in cytotoxicity compared with free drug.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/686631\" title=\"High-throughput production of microbubble contrast agents using an ultrasound-modulated microfluidic device\" class=\"state-synced\">High-throughput production of microbubble contrast agents using an ultrasound-modulated microfluidic device</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">We present an ultrasound-modulated microfluidic device for large scale production of microbubble contrast agents. Aim of this device is to overcome limitations associated with bulk production techniques or traditional microfluidic approaches. Microbubbles were characterised in terms of their dimensional and acoustical properties, and compared to those produced using bulk sonication.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/854303\" title=\"A combined magnetic-acoustic device for simultaneous, co-aligned application of magnetic and ultrasonic fields\" class=\"state-synced\">A combined magnetic-acoustic device for simultaneous, co-aligned application of magnetic and ultrasonic fields</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Acoustically-responsive microbubbles have been widely researched as agents for both diagnostic and therapeutic applications of ultrasound. Recently, there has also been considerable interest in magnetically functionalised microbubbles as multi-modality imaging agents and carriers for magnetically targeted drug delivery. The latter application in particular requires simultaneous application of magnetic and acoustic fields to a target region. This can present a significant practical challenge, especially in vivo where access is typically limited. In this paper, we present a design for an integrated device capable of generating co-aligned magnetic and acoustic fields in order to accumulate microbubbles at a specific location and then to activate them acoustically. For the purposes of this proof of concept study, the magnetic component of the device was designed to concentrate microbubbles at a distance of 10 mm from the probe\u2019s surface, commensurate with relevant tissue depths in preclinical small animal models. The ultrasound transducer was designed to maximise the acoustic intensity in the same region in order to induce cavitation of the magnetically captured microbubbles. Previous studies have indicated that both microbubble concentration and duration of cavitation activity are positively correlated with therapeutic effect. The ability of the device to trap and activate microbubbles was therefore assessed by a series of in vitro tests in a tissue mimicking phantom containing a single vessel of 1.2 mm diameter. At a flow rate of 4.2 mm/s magnetic trapping produced an increase in intensity under B-mode ultrasound imaging consistent with the predicted accumulation profile. When the microbubbles were exposed to the ultrasound field from the probe, the resulting cavitation activity was sustained for a period more than 4 times longer than that achieved with an identical acoustic field but in the absence of a magnet. The feasibility of developing a larger scale device for human applications is discussed.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/854296\" title=\"Layered acoustofluidic resonators for the simultaneous optical and acoustic characterisation of cavitation dynamics, microstreaming, and biological effects.\" class=\"state-synced\">Layered acoustofluidic resonators for the simultaneous optical and acoustic characterisation of cavitation dynamics, microstreaming, and biological effects.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">The study of the effects of ultrasound-induced acoustic cavitation on biological structures is an active field in biomedical research. Of particular interest for therapeutic applications is the ability of oscillating microbubbles to promote both cellular and tissue membrane permeabilisation and to improve the distribution of therapeutic agents in tissue through extravasation and convective transport. The mechanisms that underpin the interaction between cavitating agents and tissues are, however, still poorly understood. One challenge is the practical difficulty involved in performing optical microscopy and acoustic emissions monitoring simultaneously in a biologically compatible environment. Here we present and characterise a microfluidic layered acoustic resonator (\u03bcLAR) developed for simultaneous ultrasound exposure, acoustic emissions monitoring, and microscopy of biological samples. The \u03bcLAR facilitates in vitro ultrasound experiments in which measurements of microbubble dynamics, microstreaming velocity fields, acoustic emissions, and cell-microbubble interactions can be performed simultaneously. The device and analyses presented provide a means of performing mechanistic in vitro studies that may benefit the design of predictable and effective cavitation-based ultrasound treatments.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/1335036\" title=\"Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams.\" class=\"state-synced\">Physical Vein Models to Quantify the Flow Performance of Sclerosing Foams.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Foam sclerotherapy is clinically employed to treat varicose veins. It involves intravenous injection of foamed surfactant agents causing endothelial wall damage and vessel shrinkage, leading to subsequent neovascularization. Foam production methods used clinically include manual techniques, such as the Double Syringe System (DSS) and Tessari (TSS) methods. Pre-clinical in-vitro studies are conducted to characterize the performance of sclerosing agents; however, the experimental models used often do not replicate physiologically relevant physical and biological conditions. In this study, physical vein models (PVMs) were developed and employed for the first time to characterize the flow behavior of sclerosing foams. PVMs were fabricated in polydimethylsiloxane (PDMS) by replica molding, and were designed to mimic qualitative geometrical characteristics of veins. Foam behavior was investigated as a function of different physical variables, namely (i) geometry of the vein model (i.e., physiological vs. varicose vein), (ii) foam production technique, and (iii) flow rate of a blood surrogate. The experimental set-up consisted of a PVM positioned on an inclined platform, a syringe pump to control the flow rate of a blood substitute, and a pressure transducer. The static pressure of the blood surrogate at the PVM inlet was measured upon foam administration. The recorded pressure-time curves were analyzed to quantify metrics of foam behavior, with a particular focus on foam expansion and degradation dynamics. Results showed that DSS and TSS foams had similar expansion rate in the physiological PVM, whilst DSS foam had lower expansion rate in the varicose PVM compared to TSS foam. The degradation rate of DSS foam was lower than TSS foam, in both model architectures. Moreover, the background flow rate had a significant effect on foam behavior, enhancing foam displacement rate in both types of PVM.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n", 
        "\n\n    <div class=\"listing-item listing-item-search\" itemscope itemprop=\"itemListElement\" itemtype=\"http://schema.org/ListItem\">\n        \n        <div class=\"media-body\">\n        \n            <h4 class=\"media-heading\">\n                <a href=\"https://www.ndorms.ox.ac.uk/publications/1331752\" title=\"Early biofilm and streamer formation is mediated by wall shear stress and surface wettability: A multifactorial microfluidic study.\" class=\"state-synced\">Early biofilm and streamer formation is mediated by wall shear stress and surface wettability: A multifactorial microfluidic study.</a>\n            </h4>\n            \n            \n            \n            \n                <p data-truncate=\"yes\" data-truncate-lines=\"2\">Biofilms are intricate communities of microorganisms encapsulated within a self-produced matrix of extra-polymeric substances (EPS), creating complex three-dimensional structures allowing for liquid and nutrient transport through them. These aggregations offer constituent microorganisms enhanced protection from environmental stimuli-like fluid flow-and are also associated with higher resistance to antimicrobial compounds, providing a persistent cause of concern in numerous sectors like the marine (biofouling and aquaculture), medical (infections and antimicrobial resistance), dentistry (plaque on teeth), food safety, as well as causing energy loss and corrosion. Recent studies have demonstrated that biofilms interact with microplastics, often influencing their pathway to higher trophic levels. Previous research has shown that initial bacterial attachment is affected by surface properties. Using a microfluidic flow cell, we have investigated the relationship between both wall shear stress (\u03c4w ) and surface properties (surface wettability) upon biofilm formation of two species (Cobetia marina and Pseudomonas aeruginosa). We investigated biofilm development on low-density polyethylene (LDPE) membranes, Permanox\u00ae slides, and glass slides, using nucleic acid staining and end-point confocal laser scanning microscopy. The results show that flow conditions affect biomass, maximum thickness, and surface area of biofilms, with higher \u03c4w (5.6\u2009Pa) resulting in thinner biofilms than lower \u03c4w (0.2\u2009Pa). In addition, we observed differences in biofilm development across the surfaces tested, with LDPE typically demonstrating more overall biofilm in comparison to Permanox\u00ae and glass. Moreover, we demonstrate the formation of biofilm streamers under laminar flow conditions within straight micro-channels.</p>\n            \n\n            \n                                \n        </div>\n        \n    </div>\n\n\n"
    ], 
    "more": "\n\n    \n        <a href=\"https://www.ndorms.ox.ac.uk/news/blog/the-oxford-biopatch/search?b_start:int=40&amp;tab=publication&amp;format=json&amp;random=aa85d65b-1630-4bbd-ac74-57ba18154162&amp;09b5cafe-76e7-11ef-86ad-83ac88b73749=\" title=\"Load more\" class=\"btn btn-default load-more-button\">\n            Load More\n        </a>\n    \n\n", 
    "msg": ""
}