Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND & AIMS: In isolation, computer-aided detection (CAD) for computed tomographic (CT) colonography is as effective as optical colonoscopy for detection of significant adenomas. However, the unavoidable interaction between CAD and the reader has not been addressed. METHODS: Ten readers trained in CT but without special expertise in colonography interpreted CT colonography images of 107 patients (60 with 142 polyps), first without CAD and then with CAD after temporal separation of 2 months. Per-patient and per-polyp detection were determined by comparing responses with known patient status. RESULTS: With CAD, 41 (68%; 95% confidence interval [CI], 55%-80%) of the 60 patients with polyps were identified more frequently by readers. Per-patient sensitivity increased significantly in 70% of readers, while specificity dropped significantly in only one. Polyp detection increased significantly with CAD; on average, 12 more polyps were detected by each reader (9.1%, 95% CI, 5.2%-12.8%). Small- (< or =5 mm) and medium-sized (6-9 mm) polyps were significantly more likely to be detected when prompted correctly by CAD. However, overall performance was relatively poor; even with CAD, on average readers detected only 10 polyps (51.0%) > or =10 mm and 24 (38.2%) > or =6 mm. Interpretation time was shortened significantly with CAD: by 1.9 minutes (95% CI, 1.4-2.4 minutes) for patients with polyps and by 2.9 minutes (95% CI, 2.5-3.3 minutes) for patients without. Overall, 9 readers (90%) benefited significantly from CAD, either by increased sensitivity and/or by reduced interpretation time. CONCLUSIONS: CAD for CT colonography significantly increases per-patient and per-polyp detection and significantly reduces interpretation times but cannot substitute for adequate training.

Original publication

DOI

10.1053/j.gastro.2006.09.051

Type

Journal article

Journal

Gastroenterology

Publication Date

12/2006

Volume

131

Pages

1690 - 1699

Keywords

Adenoma, Colon, Colonic Neoplasms, Colonic Polyps, Colonography, Computed Tomographic, Diagnosis, Computer-Assisted, Humans, Professional Competence, Radiographic Image Interpretation, Computer-Assisted, Reproducibility of Results, Sensitivity and Specificity