We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

OBJECTIVE: To assess whether a standardization exercise prior to commencing a fetal growth study involving multiple sonographers can reduce interobserver variation. METHODS: In preparation for an international study assessing fetal growth, nine experienced sonographers from eight countries participated in a standardization exercise consisting of theoretical and practical sessions. Each performed a set of seven standard fetal measurements on pregnant volunteers at 20-37 weeks' gestation, and these were repeated by the lead sonographer; all measurements were taken in a blinded fashion. After this the sonographers had hands-on practice and feedback sessions on other volunteers. This process was repeated three times. Measurement differences between sonographers and the lead sonographer, expressed as a gestational-age-specific Z-score, between the first and third scans were compared using the Wilcoxon signed ranks test, and variance was assessed using Pitman's test. Interobserver agreement was also assessed using the intraclass correlation coefficient (ICC), and all images were scored for quality in a blinded fashion. RESULTS: At baseline the level of agreement and image scoring were high. A significant reduction in the differences between sonographers and the lead sonographer were seen for fetal biometry overall (head circumference, abdominal circumference and femur length) between the first and third scans (median Z-scores, 0.46 and 0.24; P = 0.005), and a reduction in the variance was also observed (P < 0.001). The ICCs for measurement pairs for every fetal measurement showed a clear trend of increasing ICC (better agreement) with consecutive training scan sessions, although no improvement in image scores was seen. CONCLUSION: Even for experienced sonographers, a standardization exercise before starting a study of fetal biometry can improve consistency of measurements. This could be of relevance for studies assessing fetal growth in multicenter sites.

Original publication

DOI

10.1002/uog.8997

Type

Journal article

Journal

Ultrasound obstet gynecol

Publication Date

12/2011

Volume

38

Pages

681 - 687

Keywords

Biometry, Clinical Competence, Female, Fetal Development, Gestational Age, Humans, Male, Observer Variation, Pregnancy, Quality Control, Quality Improvement, Reference Standards, Reproducibility of Results, Ultrasonography, Prenatal