We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: Patient-specific instrumentation (PSI) has been proposed as a means of improving surgical accuracy and ease of implantation during technically challenging procedures such as unicompartmental knee arthroplasty (UKA). The purpose of this prospective randomised controlled trial was to compare the accuracy of implantation and functional outcome of mobile-bearing medial UKAs implanted with and without PSI by experienced UKA surgeons. METHODS: Mobile-bearing medial UKAs were implanted in 43 patients using either PSI guides or conventional instrumentation. Intra-operative measurements, meniscal bearing size implanted, and post-operative radiographic analyses were performed to assess component positioning. Functional outcome was determined using the Oxford Knee Score (OKS). RESULTS: PSI guides could not be used in three cases due to concerns regarding accuracy and registration onto native anatomy, particularly on the tibial side. In general, similar component alignment and positioning was achieved using the two systems (n.s. for coronal/sagittal alignment and tibial coverage). The PSI group had greater tibial slope (p = 0.029). The control group had a higher number of optimum size meniscal bearing inserted (95 vs 52%; p = 0.001). There were no differences in OKS improvements (n.s). CONCLUSION: Component positioning for the two groups was similar for the femur but less accurate on the tibial side using PSI, often with some unnecessarily deep resections of the tibial plateau. Although PSI was comparable to conventional instrumentation based on OKS improvements at 12 months, we continue to use conventional instrumentation for UKA at our institution until further improvements to the PSI guides can be demonstrated. LEVEL OF EVIDENCE: Therapeutic, Level I.

Original publication

DOI

10.1007/s00167-017-4677-5

Type

Journal article

Journal

Knee surg sports traumatol arthrosc

Publication Date

06/2018

Volume

26

Pages

1662 - 1670

Keywords

Arthroplasty, Knee, Patient-specific instrumentation, Unicompartmental knee arthroplasty, Aged, Aged, 80 and over, Arthroplasty, Replacement, Knee, Female, Humans, Imaging, Three-Dimensional, Joint Diseases, Knee Joint, Male, Middle Aged, Patient-Specific Modeling, Prospective Studies, Recovery of Function, Surgery, Computer-Assisted