We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

BACKGROUND: Previous meta-analyses have investigated the relative safety and efficacy profiles of different types of drug-eluting stents (DES) and bare-metal stents (BMS); however, most prior trials in these meta-analyses reported follow-up to only 1 year, and as such, the relative long-term safety and efficacy of these devices are unknown. Many recent studies have now reported extended follow-up data. OBJECTIVES: This study sought to investigate the long-term safety and efficacy of durable polymer-based DES, bioabsorbable polymer-based biolimus-eluting stents (BES), and BMS by means of network meta-analysis. METHODS: Randomized controlled trials comparing DES to each other or to BMS were searched through MEDLINE, EMBASE, and Cochrane databases and proceedings of international meetings. Information on study design, inclusion and exclusion criteria, sample characteristics, and clinical outcomes was extracted. RESULTS: Fifty-one trials that included a total of 52,158 randomized patients with follow-up duration ≥3 years were analyzed. At a median follow-up of 3.8 years, cobalt-chromium everolimus-eluting stents (EES) were associated with lower rates of mortality, definite stent thrombosis (ST), and myocardial infarction than BMS, paclitaxel-eluting stents (PES), and sirolimus-eluting stents (SES) and less ST than BES. Phosphorylcholine-based zotarolimus-eluting stents had lower rates of definite ST than SES and lower rates of myocardial infarction than BMS and PES. The late rates of target-vessel revascularization were reduced with all DES compared with BMS, with cobalt-chromium EES, platinum chromium-EES, SES, and BES also having lower target-vessel revascularization rates than PES. CONCLUSIONS: After a median follow-up of 3.8 years, all DES demonstrated superior efficacy compared with BMS. Among DES, second-generation devices have substantially improved long-term safety and efficacy outcomes compared with first-generation devices.

Original publication

DOI

10.1016/j.jacc.2015.04.017

Type

Journal article

Journal

J am coll cardiol

Publication Date

16/06/2015

Volume

65

Pages

2496 - 2507

Keywords

bare-metal stent(s), drug-eluting stent(s), meta-analysis, stent thrombosis, Drug-Eluting Stents, Follow-Up Studies, Humans, Metals, Myocardial Infarction, Percutaneous Coronary Intervention, Randomized Controlled Trials as Topic, Stents, Thrombosis, Time Factors, Treatment Outcome