Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

OBJECTIVES: Primary: describe uptake of new implant components (femoral stem or acetabular cup/shell) for total hip replacements (THRs) in the National Joint Registry for England and Wales (NJR). Secondary: compare the characteristics of: (a) surgeons and (b) patients who used/received new rather than established components. DESIGN: Cohort of 618 393 primary THRs performed for osteoarthritis (±other indications) by 4979 surgeons between 2008 and 2017 in England and Wales from the NJR. We described the uptake of new (first recorded use >2008, used within 5 years) stems/cups, and variation in uptake by surgeons (primary objectives). We explored surgeon-level and patient-level factors associated with use/receipt of new components with logistic regression models (secondary objectives). OUTCOMES: Primary outcomes: total number of new cups/stems, proportion of operations using new versus established components. SECONDARY OUTCOMES: odds of: (a) a surgeon using a new cup/stem in a calendar-year, (b) a patient receiving a new rather than established cup/stem. RESULTS: Sixty-eight new cups and 72 new stems were used in 47 606 primary THRs (7.7%) by 2005 surgeons (40.3%) 2008-2017. Surgeons used a median of one new stem and cup (25%-75%=1-2 both, max=10 cups, max=8 stems). Surgeons performed a median total of 22 THRs (25%-75%=5-124, range=1-3938) in the period 2008-2017. Surgeons used new stems in a median of 5.0% (25%-75%=1.3%-16.1%) and new cups in a median of 9.4% (25%-75%=2.8%-26.7%) of their THRs. Patients aged <55 years old versus those 55-80 had higher odds of receiving a new rather than established stem (OR=1.83, 95% CI=1.73-1.93) and cup (OR=1.31, 95% CI=1.25-1.37). Women had lower odds of receiving a new stem (OR=0.87, 95% CI=0.84-0.90), higher odds of receiving a new cup (OR=1.06, 95% CI=1.03-1.09). CONCLUSIONS: Large numbers of new THR components have been introduced in the NJR since 2008. 40% of surgeons have tried new components, with wide variation in how many types and frequency they have been used.

More information Original publication

DOI

10.1136/bmjopen-2019-029572

Type

Journal article

Publication Date

2019-11-25T00:00:00+00:00

Volume

9

Keywords

implant, joint replacement, national joint registry, orthopaedics, patient, surgeon, Acetabulum, Arthroplasty, Replacement, Hip, Cohort Studies, England, Follow-Up Studies, Hip Prosthesis, Humans, Osteoarthritis, Hip, Prosthesis Design, Prosthesis Failure, Registries, Retrospective Studies, Wales