Test-retest Reliability for HAQ-DI and SF-36 PF for the Measurement of Physical Function in Psoriatic Arthritis.
Leung YY., Tillett W., Hojgaard P., Orbai A-M., Holland R., Mathew AJ., Goel N., Chau J., Lindsay CA., Ogdie A., Coates LC., Christensen R., Mease PJ., Strand V., Gladman DD.
OBJECTIVE: Due to no existing data, we aimed to derive evidence to support test-retest reliability for the Health Assessment Questionnaire-Disability Index (HAQ-DI) and 36-item Short Form Health Survey physical functioning domain (SF-36 PF) in psoriatic arthritis (PsA). METHODS: We identified datasets that collected relevant data for test-retest reliability for HAQ-DI and SF-36 PF, and evaluated them using Outcome Measures in Rheumatology (OMERACT) Filter 2.1 methodology. We calculated intraclass correlation coefficients (ICC) as a measure of test-retest reliability. We then conducted a quality assessment and evaluated the adequacy of test-retest reliability performance. RESULTS: Two datasets were identified for HAQ-DI and 1 for SF-36 PF in PsA. The quality of the datasets was good. The ICCs for HAQ-DI were good and excellent in study 1 (0.90, 95% CI 0.79-0.95) and study 2 (0.94, 95% CI 0.89-0.97). The ICC for SF-36 PF was excellent (0.96, 95% CI 0.92-0.98). The performance of test-retest reliability for both instruments was judged to be adequate. CONCLUSION: The new data derived support good and reasonable test-retest reliability for HAQ-DI and SF-36 PF in PsA.