We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

PURPOSE: Given an increasingly overweight population, unicompartmental knee replacements (UKRs) are being performed in patients with higher body mass indices (BMIs). There are concerns that cemented fixation will not last. Cementless fixation may offer a solution, but the long term results in different BMI groups has not been assessed. We studied the effect of BMI on the outcomes of cementless UKRs. METHODS: A prospective cohort of 1000 medial cementless mobile-bearing UKR with a mean follow up of 6.6 years (SD 2.7) were analysed. UKRs were categorised into four BMI groups: (1) ≥ 18.5 to < 25 kg/m2 (normal), (2) 25 to < 30 kg/m2 (overweight), (3) 30 to < 35 kg/m2 (obese class 1) and (4) ≥ 35 kg/m2 (obese class 2). Implant survival was assessed using endpoints reoperation and revision. Functional outcomes were assessed. RESULTS: Ten-year cumulative revision rate for the normal (n = 186), overweight (n = 434), obese class 1 (n = 213) and obese class 2 (n = 127) groups were 1.8% (CI 0.4-7.4), 2.6% (CI 1.3-5.1), 3.8% (CI 1.5-9.2) and 1.7% (CI 0.4-6.8) with no significant differences between groups (p = 0.79). The 10-year cumulative reoperation rates were 2.7% (CI 0.8-8.2), 3.8% (CI 2.2-6.6), 5.2% (CI 2.5-10.7) and 1.7% (CI 0.4-6.8) with no significant differences between groups (p = 0.44). The 10-year median Oxford Knee Score were 43.0, 46.0, 44.0 and 38.0 respectively. CONCLUSION: Cementless mobile-bearing UKR has low 10-year reoperation and revision rates across in all BMI groups, and there are no significant differences between the groups. Although higher BMI groups had slightly worse functional outcomes, the improvement in function compared to preoperatively tended to be better. This study suggests that BMI should not be considered a contraindication for the cementless mobile-bearing UKR.

More information Original publication

DOI

10.1007/s00167-021-06549-0

Type

Journal article

Publication Date

2023-02-01T00:00:00+00:00

Volume

31

Pages

608 - 618

Total pages

10

Keywords

Body mass index, Cementless fixation, Mid-long term outcomes, Unicondylar knee replacement, Humans, Knee Prosthesis, Body Mass Index, Prospective Studies, Overweight, Prosthesis Design, Reoperation, Obesity, Osteoarthritis, Knee, Treatment Outcome, Prosthesis Failure