We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Cardiac CT is a rapidly advancing technology. Non-invasive CT coronary angiography is an established technique for assessing coronary heart disease with accuracy similar to invasive coronary angiography. CT myocardial perfusion imaging can now identify perfusion defects in animal models and humans. MRI is the current 'gold standard' for the assessment of myocardial viability, but it is now also possible to assess delayed enhancement by CT. This has led to the possibility of a 'one-stop shop' for cardiovascular imaging that would provide information on anatomy, function, perfusion and viability in one rapid diagnostic test at a radiation dose equivalent to contemporary nuclear medicine imaging. This review discusses the current status of 'one-stop shop' cardiac CT assessment, clinical utility and directions for future research.

Original publication

DOI

10.1136/heartjnl-2011-300037

Type

Journal article

Journal

Heart

Publication Date

08/2011

Volume

97

Pages

1198 - 1205

Keywords

Animals, Coronary Angiography, Coronary Circulation, Coronary Disease, Humans, Magnetic Resonance Imaging, Myocardial Perfusion Imaging, Reproducibility of Results, Tomography, X-Ray, Ventricular Function