Bile duct anatomy depicted with a three-dimensional (3D) model developed with helical computed tomography (CT) data was compared with cholangiographic depiction. The ductal system was completely displayed from all angles in four of six patients, as well as the stricture and length of bile duct between strictures and the bifurcation in five of six cases. 3D rendering can depict preoperative ductal anatomy.

Original publication

DOI

10.1148/radiology.196.3.7644658

Type

Journal article

Journal

Radiology

Publication Date

09/1995

Volume

196

Pages

865 - 867

Addresses

Department of Radiology, Georgetown University Medical Center, Washington, DC 20007, USA.

Keywords

Humans, Carcinoma, Pancreatic Neoplasms, Cholestasis, Constriction, Pathologic, Contrast Media, Tomography, X-Ray Computed, Radiographic Image Enhancement, Cholangiography, Feasibility Studies, Data Display, Adult, Aged, Middle Aged, Female, Male