We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

INTRODUCTION: We aimed to investigate the sensitivity and reliability of two-dimensional ultrasonographic endpoints at the metacarpophalageal joints (MCPJs) and their potential to provide an early and objective indication of a therapeutic response to treatment intervention in rheumatoid arthritis (RA). METHODS: A randomized, double-blind, parallel-group, two-center, placebo-controlled trial investigated the effect on ultrasonographic measures of synovitis of repeat dose oral prednisone, 15 mg or 7.5 mg, each compared to placebo, in consecutive two-week studies; there were 18 subjects in a 1:1 ratio and 27 subjects in a 2:1 ratio, respectively. All subjects met the 1987 American College of Rheumatology criteria for the diagnosis of RA, were ≥18 years-old with RA disease duration ≥6 months, and had a Disease Activity Score 28 based on C-reactive protein (DAS28(CRP)) ≥3.2. Subjects underwent high-frequency (gray-scale) and power Doppler ultrasonography at Days 1 (baseline), 2, 8 and 15 in the dorsal transverse and longitudinal planes of all 10 MCPJs to obtain summated scores of quantitative and semi-quantitative measures of synovial thickness as well as vascularity. The primary endpoint was the summated score of power Doppler area measured quantitatively in all 10 MCPJs in the transverse plane at Day 15. Clinical efficacy was assessed at the same time points by DAS28(CRP). RESULTS: All randomized subjects completed the trial. The comparison between daily 15 mg prednisone and placebo at Day 15 yielded a statistically significant treatment effect (effect size = 1.17, P = 0.013) in change from baseline in the primary endpoint, but borderline for prednisone 7.5 mg daily versus placebo (effect size = 0.61, P = 0.071). A significant treatment effect for DAS28(CRP) was only observed at Day 15 in the prednisone 15 mg group (effect size = 0.95, P = 0.032). However, significant treatment effects at all time points for a variety of ultrasound (US) endpoints were detected with both prednisone doses; the largest observed effect size = 2.33. Combining US endpoints with DAS28(CRP) improved the registration of significant treatment effects. The parallel scan inter-reader reliability of summated 10 MCPJ scores were good to excellent (ICC values >0.61) for the majority of US measures. CONCLUSIONS: Ultrasonography of MCPJs is an early, reliable indicator of therapeutic response in RA with potential to reduce patient numbers and length of trials designed to give preliminary indications of efficacy. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT00746512.

Original publication

DOI

10.1186/ar4034

Type

Journal article

Journal

Arthritis res ther

Publication Date

12/09/2012

Volume

14

Keywords

Adult, Aged, Aged, 80 and over, Antirheumatic Agents, Arthritis, Rheumatoid, Biomarkers, C-Reactive Protein, Dose-Response Relationship, Drug, Double-Blind Method, Endpoint Determination, Female, Humans, Male, Metacarpophalangeal Joint, Middle Aged, Prednisone, Reproducibility of Results, Sensitivity and Specificity, Treatment Outcome, Ultrasonography