We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Although quantitative ultrasound (QUS) is known to be correlated with BMD and bone structure, its long-term predictive power for fractures in comparison with DXA is unclear. We examined this in a sample of men and women in the European Prospective Investigation into Cancer (EPIC)-Norfolk who had both heel QUS and hip DXA between 1995 and 1997. From 1455 participants (703 men) 65-76 yr of age at baseline, 79 developed a fracture over 10.3 +/- 1.4 yr of follow-up. In a sex-stratified Cox proportional-hazard model including age, height, body mass index, prior fracture, smoking, alcohol intake, and total hip BMD, a 1 SD decrease in BMD was associated with a hazard ratio (HR) for fracture of 2.26 (95% CI: 1.74-2.95). In the multivariable model with heel broadband ultrasound attenuation (BUA) in place of BMD, HR for a 1 SD decrease in BUA was 2.04 (95% CI: 1.55-2.69). Global measures of model fit showed relative superiority of the BMD model, whereas the area under the receiving operator characteristic (ROC) curve was slightly higher for the BUA model. Using both Cox models with BMD and BUA measures, we calculated exact 10-yr absolute risk of fracture for all participants and categorized them in groups of <5%, 5% to <15%, and >or=15%. Comparison of groupings based on two models showed a total reclassification of 28.8% of participants, with the greatest reclassification (approximately 40%) among the intermediate- and high-risk groups. This study shows that the power of QUS for prediction of fractures among the elderly is at least comparable to that of DXA. Given the feasibility and lower cost of ultrasound measurement in primary care, further studies to develop and validate models for prediction of 10-yr risk of fracture using clinical risk factors and QUS are recommended.

Original publication

DOI

10.1359/jbmr.090212

Type

Journal article

Journal

J bone miner res

Publication Date

07/2009

Volume

24

Pages

1319 - 1325

Keywords

Absorptiometry, Photon, Adult, Age Factors, Aged, Bone Density, Female, Follow-Up Studies, Fractures, Bone, Humans, Male, Middle Aged, Models, Biological, Prospective Studies, ROC Curve, Risk Factors, Sex Factors, Ultrasonography