Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

We present an economic evaluation using data from the Distal Radius Acute Fracture Fixation Trial (DRAFFT) to compare the relative cost effectiveness of percutaneous Kirschner wire (K-wire) fixation and volar locking-plate fixation for patients with dorsally-displaced fractures of the distal radius. The cost effectiveness analysis (cost per quality-adjusted life year; QALY) was derived from a multi-centre, two-arm, parallel group, assessor-blind, randomised controlled trial which took place in 18 trauma centres in the United Kingdom. Data from 460 patients were available for analysis, which includes both a National Health Service cost perspective including costs of surgery, implants and healthcare resource use over a 12-month period after surgery, and a societal perspective, which includes the cost of time off work and the need for additional private care. There was only a small difference in QALYs gained for patients treated with locking-plate fixation over those treated with K-wires. At a mean additional cost of £714 (95% confidence interval 588 to 865) per patient, locking-plate fixation presented an incremental cost effectiveness ratio (ICER) of £89,322 per QALY within the first 12 months of treatment. Sensitivity analyses were undertaken to assess the ICER of locking-plate fixation compared with K-wires. These were greater than £30,000. Compared with locking-plate fixation, K-wire fixation is a 'cost saving' intervention, with similar health benefits.

Original publication

DOI

10.1302/0301-620X.97B8.35234

Type

Journal article

Journal

Bone joint j

Publication Date

08/2015

Volume

97-B

Pages

1082 - 1089

Keywords

economic evaluation; QALY; within-trial; K-wire; distal radius fracture; volar locking-plate, Bone Plates, Bone Wires, Cost-Benefit Analysis, Female, Fracture Fixation, Internal, Humans, Length of Stay, Male, Palmar Plate, Quality-Adjusted Life Years, Radius Fractures, State Medicine