Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Background and purpose - Registries report high revision rates after unicompartmental knee replacement (UKR) due, in part, to aseptic loosing. In an attempt to improve Oxford UKR femoral component fixation a new design was introduced with a Twin rather than a Single peg. We used the National Joint Registry (NJR) to compare the 5-year outcomes of the Single and Twin Peg cemented Oxford UKRs.Patients and methods - We performed a retrospective observational study using NJR data on propensity score matched Single and Twin Peg UKRs (matched for patient, implant and surgical factors). Data on 2,834 Single Peg and 2,834 Twin Peg were analyzed. Cumulative implant survival was calculated using the Kaplan-Meier method and comparisons between groups performed using Cox regression models.Results - In the matched cohort, the mean follow up for both Single and Twin Peg UKRs was 3.3 (SD 2) and 3.4 years (SD 2) respectively. The 5-year cumulative implant survival rates for Single Peg and Twin Peg were 94.8% (95% CI 93.6-95.8) and 96.2% (CI 95.1-97.1) respectively. Implant revision rates were statistically significantly lower in the Twin Peg (hazard ratio [HR)] = 0.74; p = 0.04). The revision rate for femoral component aseptic loosening decreased significantly (p = 0.03) from 0.4% (n = 11) with the Single Peg to 0.1% (n = 3) with the Twin Peg. The revision rate for pain decreased significantly (p = 0.01) from 0.8% (n = 23) with the Single Peg to 0.3% (n = 9) with the Twin Peg. No other reasons for revision had significant differences in revision rates.Interpretation - The revision rate for the cemented Twin Peg Oxford UKR was 26% less than the Single Peg Oxford UKR. This was mainly because the revision rates for femoral loosening and pain more than halved. This suggests that the Twin Peg component should be used in preference to the Single Peg design.

Original publication

DOI

10.1080/17453674.2020.1748288

Type

Journal article

Journal

Acta orthop

Publication Date

08/2020

Volume

91

Pages

420 - 425

Keywords

Aged, Arthroplasty, Replacement, Knee, England, Female, Humans, Knee Prosthesis, Male, Northern Ireland, Prosthesis Failure, Registries, Reoperation, Retrospective Studies, United Kingdom, Wales