We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Multi-parametric MR image registration combines different imaging sequences to enhance visualisation and analysis. However, alignment of the different acquisitions is challenging, due to contrast-dependent anatomical information and abundant artefacts. For two decades, voxel-based registration has been dominated by methods based on mutual information, calculated from the joint image histogram. In this paper, we propose a modified framework - based on an asymmetric cluster-to-image mutual information metric - that increases registration speed and robustness. A new parameter, the homogeneous dynamic intensity range, is used to determine to which image clustering is applied. The framework also includes a semi-automatic 3D region of interest, multi-resolution wavelet decomposition, and particle swarm optimization. Performance of the framework, and its individual components, were evaluated on two diverse datasets, comprising cardiac and neonatal brain datasets. The results demonstrated the method was more robust and accurate than mutual information alone.

Original publication

DOI

10.1109/ISBI.2015.7164061

Type

Conference paper

Publication Date

21/07/2015

Volume

2015-July

Pages